Epson UB E02 Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware Epson UB E02. Epson UB E02 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 86
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
UB-E02
Technical Reference
Guide
10Base-T/100Base-TX
Ethernet Interface board
EPSON
English
404999001
Vedere la pagina 0
1 2 3 4 5 6 ... 85 86

Sommario

Pagina 1 - Technical Reference

UB-E02Technical Reference Guide10Base-T/100Base-TXEthernet Interface boardEPSONEnglish404999001

Pagina 2

viii Rev. ASupported TM PrintersThe following printers can use the UB-E02. (The TM-J8000, TM-T285, and RP-U420 cannot use the UB-E02. For new model

Pagina 3 - Rev. A i

Rev. A ixUB-E02 Technical Reference GuideHow to Use this GuideInstallation OverviewBe sure to read Chapter 1, “System Preparation,” before using the p

Pagina 4 - Revision Information

x Contents Rev. AContentsChapter 1 System PreparationSupported Operating Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 5 - About This Guide

Rev. A Contents xiUB-E02 Technical Reference GuideChapter 5 SpecificationsPrinter Connection . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 7 - WARNING:

Rev. A System Preparation 1-1UB-E02 Technical Reference GuideChapter 1 System Preparation1.1 Supported Operating Systems❏ Microsoft Windows 95, Win

Pagina 8

1-2 System Preparation Rev. AThe following printers cannot use the UB-E02.❏ TM-J8000, TM-T285, RP-U4201.4 Other LimitationsBe sure to note the foll

Pagina 9 - Operating Environments

Rev. A Installation 2-1UB-E02 Technical Reference GuideChapter 2Installation2.1 Installation PrecautionsWARNING ❏Before installing, disconnect the

Pagina 10 - Supported TM Printers

2-2 Installation Rev. A2.2 Unpacking❏ UB-E02❏ UB-E02 User’s Manual2.3 Part NamesNote: This photograph shows the TM-T88III printer with the UB-E02

Pagina 11 - How to Use this Guide

Rev. A Installation 2-3UB-E02 Technical Reference Guide2.5 UB-E02 InstallationCAUTION:Before installing the UB-E02, be sure to set the DIP switches

Pagina 13 - Appendix A Definitions

2-4 Installation Rev. A3. Tighten the screws.If you have removed an interface circuit board that was already installed, fix the UB-E02 using the rem

Pagina 14

Rev. A Installation 2-5UB-E02 Technical Reference GuideNote:When initializing the UB-E02 by turning off the power and then turning it back on or by

Pagina 15 - Chapter 1

2-6 Installation Rev. A7. Print a status sheet to check whether the UB-E02 is installed correctly by holding the switch down for more than 3 seconds

Pagina 16 - CAUTION:

Rev. A Installation 2-7UB-E02 Technical Reference Guide2.6 Initializing UB-E02All the parameters of internal settings for the UB-E02 can be set to

Pagina 17 - Chapter 2

2-8 Installation Rev. A2.8 FAQ2.8.1 Q1. The printer does not operate correctly. ("Serial interface" is printed by the self test for the

Pagina 18 - 2.4 Functions

Rev. A Installation 2-9UB-E02 Technical Reference Guide2.8.3.1 A3. When the auto setting is set for IP address acquisition without a DHCP server, st

Pagina 19

2-10 Installation Rev. A

Pagina 20

Rev. A Utilities 3-1UB-E02 Technical Reference GuideChapter 3 Utilities3.1 Setting the IP AddressTo use the UB-E02 with TCP/IP, you first need to s

Pagina 21

3-2 Utilities Rev. AWindows 951. Double-click the Network icon in the Control Panel; then check whether TCP/IP is in the list of installed network c

Pagina 22 - 2-6 Installation Rev. A

Rev. A Utilities 3-3UB-E02 Technical Reference Guide3. Select Microsoft from the list of manufacturers and TCP/IP from the Network protocols list. T

Pagina 23

Rev. A iUB-E02 Technical Reference GuideCAUTIONS❏ This document shall apply only to the product(s) identified herein.❏ No part of this document may be

Pagina 24 - 2.8 FAQ

3-4 Utilities Rev. AWindows NT 4.01. Double-click the Network icon in the Control Panel to check whether the TCP/IP Protocol is installed. If it is

Pagina 25 - Rev. A Installation 2-9

Rev. A Utilities 3-5UB-E02 Technical Reference Guide3. If you continue installing the TCP/IP protocol, the TCP/IP Configuration dialog box appears,

Pagina 26 - 2-10 Installation Rev. A

3-6 Utilities Rev. A2. Click Properties and check whether the Internet Protocol (TCP/IP) check box is checked. If not, click the check box.Note:Afte

Pagina 27 - Utilities

Rev. A Utilities 3-7UB-E02 Technical Reference GuideInstallation with Windows 951. Unzip the file and start Setup.exe.2. Install the EPSON TMNet Win

Pagina 28 - Windows 95

3-8 Utilities Rev. A3.1.1.3 Setting with the EPSON TMNet WinConfig CAUTION:Because the same IP address is set for all UB-E02 units in the factory, d

Pagina 29

Rev. A Utilities 3-9UB-E02 Technical Reference Guide CAUTION:When you cannot check the MAC address on the label on the UB-E02 that is installed on t

Pagina 30 - Windows NT 4.0

3-10 Utilities Rev. ANote:To confirm the current setting, print out the status sheet. Press down the switch more than 3 seconds in the printable sta

Pagina 31 - Windows 2000

Rev. A Utilities 3-11UB-E02 Technical Reference Guide3.1.2 Setting the IP Address Using the arp/ping CommandYou can set the IP Address using the ar

Pagina 32 - Installation Environments

3-12 Utilities Rev. A4. Set the IP address to the UB-E02 using the ping command.•Example: ping 192.168.100.2015. If the ping command is successful,

Pagina 33 - Installation with Windows 95

Rev. A Utilities 3-13UB-E02 Technical Reference Guide3.2 EPSON TMNet WinConfig FunctionsThis section describes the functions, including options of

Pagina 34

ii Rev. ARevision InformationRevision Page Altered Items and ContentsRev. A

Pagina 35

3-14 Utilities Rev. A3.2.1 Menu BarThe table shows each item and its function.3.2.1.1 Tool MenuTime-out settingUse Time-out setting to set the time

Pagina 36

Rev. A Utilities 3-15UB-E02 Technical Reference GuideSearch OptionsIf you want to show and set a UB-E02 that is controlled by TCP/IP and is outside

Pagina 37

3-16 Utilities Rev. A3.2.1.2 Settings PrinterYou can set the printer name. This also shows printer information.Item ExplanationPrinter name Set the

Pagina 38

Rev. A Utilities 3-17UB-E02 Technical Reference GuidePrint serverYou can set administrator information. This also shows the printer server informati

Pagina 39 - Rev. A Utilities 3-13

3-18 Utilities Rev. ATCP/IP You can set the TCP/IP.Item ExplanationGet IP address Auto or Manual is selectable for the UB-E02.Set by PING Check the

Pagina 40 - Time-out setting

Rev. A Utilities 3-19UB-E02 Technical Reference GuidePasswordThe EPSON TMNet WinConfig can set a password to protect the UB-E02 settings. The screen

Pagina 41 - Search Options

3-20 Utilities Rev. A3.3 EPSON TMNet WebConfig FunctionsThis section explains each function of the EPSON TMNet WebConfig.Note:Launch a browser and

Pagina 42 - 3.2.1.2 Settings

Rev. A Utilities 3-21UB-E02 Technical Reference GuideItem ExplanationInformation General Show the UB-E02 information.TCP/IP Show the TCP/IP informat

Pagina 43 - Print server

3-22 Utilities Rev. A3.3.2 Protocol Information and Settings3.3.2.1 General InformationItem ExplanationAdministrator nameShows the administrator na

Pagina 44 - You can set the TCP/IP

Rev. A Utilities 3-23UB-E02 Technical Reference Guide3.3.2.2 TCP/IP Information Item ExplanationGet IP Address Shows the method of setting the IP ad

Pagina 45 - Password

Rev. A iiiUB-E02 Technical Reference GuideAbout This Guide This guide is intended to provide all information necessary for system planning, design, in

Pagina 46 - 3.3.1 Opening Screen

3-24 Utilities Rev. A3.3.2.3 SNMP InformationItem ExplanationCommunity Read Only Shows he Read Community information.Read/Write Shows the Read/Write

Pagina 47 - Rev. A Utilities 3-21

Rev. A Utilities 3-25UB-E02 Technical Reference Guide3.3.2.4 TCP/IP SettingItem ExplanationGet IP Address Select the method of acquiring the IP addr

Pagina 48 - 3.3.2.1 General Information

3-26 Utilities Rev. A3.3.2.5 SNMP Communication SettingItem ExplanationCommunity Read Only The setting is fixed to “Public.”Read/Write Set the Read/

Pagina 49 - 3.3.2.2 TCP/IP Information

Rev. A Utilities 3-27UB-E02 Technical Reference Guide3.3.2.6 SNMP IP Trap 1 SettingItem ExplanationTrap Set Trap 1.Address Set the Trap 1 Address.Co

Pagina 50 - 3.3.2.3 SNMP Information

3-28 Utilities Rev. A3.3.2.7 SNMP IP Trap 2 SettingItem ExplanationTrap Set Trap 2.Address Set the Trap 2 Address.Community Name Set the Trap 2 Comm

Pagina 51 - 3.3.2.4 TCP/IP Setting

Rev. A Utilities 3-29UB-E02 Technical Reference Guide3.3.2.8 Administrator SettingItem ExplanationAdministrator Name Set the administrator name.Loca

Pagina 52 - 3-26 Utilities Rev. A

3-30 Utilities Rev. A3.3.2.9 Password SettingItem ExplanationOld Password Input the old password.New Password Input the new password.Re-input Passwo

Pagina 53 - Rev. A Utilities 3-27

Rev. A Utilities 3-31UB-E02 Technical Reference Guide3.3.2.10 ResetItem ExplanationReset Resets the UB-E02 to its status when the power was turned o

Pagina 54 - 3-28 Utilities Rev. A

3-32 Utilities Rev. A3.3.2.11 AdvancedItem ExplanationPhysical Layer Setting Set the communication method.

Pagina 55 - 3.3.2.8 Administrator Setting

Rev. A 4-1 Programming SamplesUB-E02 Technical Reference GuideChapter 4Programming SamplesThis chapter describes the following:❏ Method of printing

Pagina 56 - 3.3.2.9 Password Setting

iv Rev. AEMC and Safety Standards Applied Product Name: UB-E02Model Name: M155BThe following standards are applied only to the interface boards t

Pagina 57 - 3.3.2.10 Reset

4-2 Programming Samples Rev. A4.1 Method of Printing to the UB-E02The UB-E02 has lpr protocol as its general print protocol. It is easy to print by

Pagina 58 - 3.3.2.11 Advanced

Rev. A 4-3 Programming SamplesUB-E02 Technical Reference Guide4.2 Direct Printing by PORT91004.2.1 For Windows ConsoleThe program is a sample of p

Pagina 59 - Chapter 4

4-4 Programming Samples Rev. A /* send data */ send(sock, "EPSON\n", 6, 0); /* gracefully close */ shutdown(sock, 1);/* SD_SEND */ wh

Pagina 60 - 4.1.1 Buffer of the UB-E02

Rev. A 4-5 Programming SamplesUB-E02 Technical Reference Guide4.2.2 For LinuxThe program is a sample of printing “EPSON UB-E02” to a TM printer wit

Pagina 61 - 4.2.1 For Windows Console

4-6 Programming Samples Rev. A4.3 Commands Sent to a TM Printer When the Power is OnWhen the power is turned on, the UB-E02 transmits the following

Pagina 62

Rev. A 4-7 Programming SamplesUB-E02 Technical Reference Guide4.7 Printer Operation by the UDP CommandsBy using the UDP commands, the following inf

Pagina 63 - 4.2.2 For Linux

4-8 Programming Samples Rev. A4.7.2 03-0000 Retrieving Basic Information4.7.2.1 Reply data4.7.3 03-0010 Retrieving Status4.7.3.1 Reply dataOff-set

Pagina 64 - 4.6 Time-out for Connection

Rev. A 4-9 Programming SamplesUB-E02 Technical Reference Guide4.7.4 03-0011 Forced TransmissionTransmission is done, regardless of the flow control

Pagina 65 - 4.7.1 Commands Packets

4-10 Programming Samples Rev. A4.7.6 03-0013 Buffer Flash4.7.6.1 Reply data❏ This clears only the buffer of the UB-E02 and cannot clear the receive

Pagina 66 - 4.7.3.1 Reply data

Rev. A 4-11 Programming SamplesUB-E02 Technical Reference Guide4.7.8 Programming Sample4.7.8.1 For Windows Console/* UDP3289 programming sample for

Pagina 67 - 4.7.5.2 Reply data

Rev. A vUB-E02 Technical Reference GuideCAUTION:Connecting an outdoor overhead LAN cable directly to your productConnecting an outdoor overhead LAN ca

Pagina 68 - 4.7.7.2 Reply data

4-12 Programming Samples Rev. A buf[11] = 0x00; buf[12] = 0x00; // Parameter length buf[13] = 0x00; /* send a packet */ i = sendto(sock, buf, 1

Pagina 69 - 4.7.8.1 For Windows Console

Rev. A 4-13 Programming SamplesUB-E02 Technical Reference Guide4.7.8.2 For Linux/* UDP3289 programming sample for LINUX * HOW TO BUILD * cc ludp.c

Pagina 70

4-14 Programming Samples Rev. A buf[13] = 0x00; /* send packet */ i = sendto(sock, buf, 14, 0, (struct sockaddr*)&addr, sizeof(addr)); /* re

Pagina 71 - 4.7.8.2 For Linux

Rev. A Specifications 5-1UB-E02 Technical Reference GuideChapter 5SpecificationsThe UB-E02 can be installed in the TM-series printers as an interfac

Pagina 72

5-2 Specifications Rev. A5.3.2 Printing Functions❏ Printing by standard protocols (printing of network objects through a device driver❏ Socket prin

Pagina 73 - Specifications

Rev. A Specifications 5-3UB-E02 Technical Reference Guide5.4.3 External appearance and connector locations5.5 Software Specifications5.5.1 Basic

Pagina 74 - 5.4 Hardware Specifications

5-4 Specifications Rev. A5.5.3 Status Inquiry and Setting Protocols5.5.3.1 HTTP ❏ Port number: 80❏ User name: EPSON❏ Password: None❏ Maximum sim

Pagina 75 - 5.5.2.2 Socket Communications

Rev. A Specifications 5-5UB-E02 Technical Reference Guide❏ PDU support Get Request Get Next Request Set Request Get Response Trap❏ Server port numb

Pagina 76 - 5.5.3.2 SNMP (MIB)

5-6 Specifications Rev. A5.5.4.2 IP Address Assignment by APIPA❏ Item to acquire: IP Address❏ Range of address: 169.254.1.0 to 169.254.254.255Any IP

Pagina 77 - 5.5.3.3 ENPC

Rev. A Specifications 5-7UB-E02 Technical Reference Guide5.5.5 Internal Settings 5.5.5.1 Item List o = possible × = impossibleItem Parameter Initi

Pagina 78 - 5.5.4.3 Manual Setting

vi Rev. ASafety Precautions This section presents important information to ensure safe and effective use of this product. Please read this section

Pagina 79 - 5.5.5.1 Item List

5-8 Specifications Rev. A5.5.5.2 Internal Parameter Setting Methods1. Using the exclusive utility.2. Using a browser3. Using arp and ping commands (

Pagina 80 - 5.5.5.4 Setting with Browser

Rev. A Specifications 5-9UB-E02 Technical Reference Guide5.5.6 Initializing To initialize the UB-E02 when the power is turned on or reset, the stan

Pagina 81 - 5.5.7.2 Upgrade Methods

5-10 Specifications Rev. A5.6 Environmental Specifications Temperature:0 to 50° C {32 to 122° F} Humidity:10 to 90% RH (non-condensing) 5.7 Storag

Pagina 82 - 5.7 Storage Conditions

Rev. A Definitions A-1UB-E02 Technical Reference GuideAppendix A DefinitionsAASB— Auto Status Back: The feature that allows the printer to send the

Pagina 83 - Appendix A

A-2 Definitions Rev. ATCP/IP—Name given to the suite of protocols (including but not limited to TCP and IP) that govern the transmission and service

Pagina 85

EPSONSEIKO EPSON CORPORATION Printed in Japan

Pagina 86 - SEIKO EPSON CORPORATION

Rev. A viiUB-E02 Technical Reference GuideIntroductionThe UB-E02 is the 10Base-T/100Base-TX Ethernet interface board designed for the EPSON® TM printe

Commenti su questo manuale

Nessun commento