ESC 6
Printable Code Area Expansion
Format:
ASCII code:
ESC 6
Decimal:
27 54
Hexadecimal:
1B 36
Comments:
Enables the printing of codes 128 through 159 (decimal) as
characters, not control codes. This allows the use of these characters
for user-defined characters.
ESC 7
Cancel ESC 6
Format:
ASCII code:
ESC 7
Decimal:
27 55
Hexadecimal:
1B 37
Comments:
This code causes codes 128 through 159 to be treated as control
codes. This is the default.
ESC I
Printable Code Area Expansion
Format:
ASCII code: ESC I n
Decimal:
27 73 n
Hexadecimal: 1B
49 n
Comments:
ASCII codes 0 to 31 and 128 to 159 are usually not printable. These
codes become printable upon input of the ESC I code if n = 1,
which allows the use of these codes for user-defined characters. If
n = 0, this command returns 0 to 31 and 128 to 159 to non-
printable codes.