S1C6S2N7 TECHNICAL HARDWARE EPSON I-83
CHAPTER 6: ELECTRICAL CHARACTERISTICS
S1C6S2A7 (CR oscillation, Normal operating mode)
Unless otherwise specified
VDD=0 V, VSS=-3.0 V, fosc=200 kHz, Ta=25°C, VS1, VL1, VL2 and VL3 are internal
voltages, and C1=C2=C3=C4=C5=0.1 µF, Recommended external resistance for CR
oscillation=160 kΩ
Item
Internal voltage
SVD voltage
SVD circuit response time
Current consumption
Symbol
V
L1
V
L2
V
L3
V
SVD
t
SVD
I
OP
Condition
Connect 1MΩ load resistor between V
DD
and V
L1
(without panel load)
Connect 1MΩ load resistor between V
DD
and V
L2
(without panel load)
Connect 1MΩ load resistor between V
DD
and V
L3
(without panel load)
Min.
1/2•V
L2
-0.1
-2.25
3/2•V
L2
-0.1
-2.55
Typ.
-2.10
-2.40
60
70
Unit
V
V
V
V
µs
µA
µA
Max.
1/2•V
L2
× 0.9
-1.95
3/2•V
L2
× 0.9
-2.25
100
110
130
During HALT
During execution
∗1
Without panel load
∗1 The SVD circuit is turned OFF.
S1C6S2A7 (CR oscillation, Heavy load protection mode)
Unless otherwise specified
VDD=0 V, VSS=-3.0 V, fosc=200 kHz, Ta=25°C, VS1, VL1, VL2 and VL3 are internal
voltages, and C1=C2=C3=C4=C5=0.1 µF, Recommended external resistance for CR
oscillation=160 kΩ
∗1 The SVD circuit is turned OFF.
Item
Internal voltage
SVD voltage
SVD circuit response time
Current consumption
Symbol
V
L1
V
L2
V
L3
V
SVD
t
SVD
I
OP
Condition
Connect 1MΩ load resistor between V
DD
and V
L1
(without panel load)
Connect 1MΩ load resistor between V
DD
and V
L2
(without panel load)
Connect 1MΩ load resistor between V
DD
and V
L3
(without panel load)
Min.
1/2•V
L2
-0.1
-2.25
3/2•V
L2
-0.1
-2.55
Typ.
-2.10
-2.40
85
95
Unit
V
V
V
V
µs
µA
µA
Max.
1/2•V
L2
× 0.85
-1.95
3/2•V
L2
× 0.85
-2.25
100
160
180
During HALT